dc.description.abstract | The energy efficiency of refrigeration equipment is increasingly important for industries and buildings, due to the magnitude that such equipment represents in the consumption of electricity. In refrigeration systems the best known is the one that operates with steam compression cycle. In this cycle, the compressor is the most complex and most expensive equipment. Thus, special care must be taken, as in addition to problems such as wear and lack of lubricants, it is subject to damage due to the incorrect or faulty operation of all other components. Within the existing compressors, the reciprocating compressor can be commercially considered the workhorse of industrial refrigeration, dominating the capacity range below 300 kW (85 TRs). Thus, this project aims to experimentally analyze the performance of single and double stage refrigeration compressors used in the company's products. | pt_BR |
dc.description.resumo | A eficiência energética de equipamentos de refrigeração é cada vez mais importante para as indústrias e edificações, devido à magnitude que tais equipamentos representam no consumo de energia elétrica. Em sistemas de refrigeração o mais conhecido é o que opera com ciclo por compressão de vapor. Neste ciclo, o compressor é o equipamento mais complexo e de maior custo. Dessa forma, deve-se tomar especial cuidado, pois além de problemas como desgaste e falta de lubrificantes, ele está sujeito a sofrer danos decorrentes do funcionamento incorreto ou falho de todos os outros componentes. Dentro dos compressores existentes, o compressor alternativo pode ser comercialmente considerado o cavalo de batalha da refrigeração industrial, dominando a faixa de capacidades inferiores a 300 kW (85 TRs). Assim, este projeto tem o objetivo de analisar experimentalmente o desempenho de compressores de refrigeração de simples e duplo estágio utilizados nos produtos da empresa. | pt_BR |
dc.description.provenance | Submitted by Regiane Paulino (regiane.paulino@unis.edu.br) on 2021-04-26T17:47:45Z No. of bitstreams: 1 Lucas Faria Vazi 112114.pdf: 7189030 bytes, checksum: 37e3d1fdb74d2da18209089cd7bc91a2 (MD5) | en |
dc.description.provenance | Made available in DSpace on 2021-04-26T17:47:45Z (GMT). No. of bitstreams: 1 Lucas Faria Vazi 112114.pdf: 7189030 bytes, checksum: 37e3d1fdb74d2da18209089cd7bc91a2 (MD5) Previous issue date: 2010-12-13 | en |
dc.language | por | pt_BR |
dc.publisher | Fundação de Ensino e Pesquisa do Sul de Minas | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | Centro Universitário | pt_BR |
dc.publisher.initials | FEPESMIG | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Refrigeração | pt_BR |
dc.subject | Túnel de congelamento | pt_BR |
dc.subject | Compressor | pt_BR |
dc.subject | Semi-hermético | pt_BR |
dc.subject | Simples estágio | pt_BR |
dc.subject | Duplo estágio | pt_BR |
dc.subject.cnpq | CNPQ::ENGENHARIAS::ENGENHARIA MECANICA | pt_BR |
dc.title | COMPARAÇÃO DE COMPRESSORES BITZER EM TÚNEL DE CONGELAMENTO | pt_BR |
dc.title.alternative | LUCAS FARIA VAZI | pt_BR |
dc.type | Trabalho de Conclusão de Curso | pt_BR |