dc.description.abstractThis study aims to identify how energy efficiency measures can be applied to a company's lighting system. In view of the growth in the use of electricity, it was necessary to produce this study. The current lighting situation of a project was analyzed, understanding the basic concepts of lighting techniques and lighting standards. The objective is also to show an alternative to reduce the company's energy consumption, improving the current system. For this reduction, it was proposed the use of LED lamps, which, compared to current ones, result in greater energy efficiency, in addition to a longer service life. Finally, evaluate and propose a more efficient solution for the current lighting system.pt_BR
dc.description.resumoEste estudo tem por objetivo identificar as medidas de eficiência energética aplicáveis ao sistema de iluminação de uma empresa. Tendo em vista o crescimento da utilização de energia elétrica, verificou-se a necessidade da produção deste estudo. Foi analisado a situação atual da iluminação de um projeto, compreendendo os conceitos básicos de luminotécnicas e normas de iluminações. Objetifica-se também mostrar uma alternativa para reduzir o gasto de energia na empresa, melhorando o sistema atual. Para esta redução, foi proposto o uso das lâmpadas de LED que, comparadas às atuais, acarretam uma maior eficiência energética, além da vida útil mais longa. Por fim, avaliar e propor uma solução mais eficiente para o sistema de iluminação atual.pt_BR
dc.description.provenanceSubmitted by Regiane Paulino (regiane.paulino@unis.edu.br) on 2021-10-21T18:27:40Z No. of bitstreams: 1 TCC Weber.pdf: 750106 bytes, checksum: 243ce2eb748678123dc73e1af6492f30 (MD5)en
dc.description.provenanceMade available in DSpace on 2021-10-21T18:27:40Z (GMT). No. of bitstreams: 1 TCC Weber.pdf: 750106 bytes, checksum: 243ce2eb748678123dc73e1af6492f30 (MD5) Previous issue date: 2021-03-19en
dc.languageporpt_BR
dc.publisherFundação de Ensino e Pesquisa do Sul de Minaspt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro Universitáriopt_BR
dc.publisher.initialsFEPESMIGpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectEficiência Energéticapt_BR
dc.subjectLEDpt_BR
dc.subjectIluminaçãopt_BR
dc.subjectLuminotécnicapt_BR
dc.subjectEconomiapt_BR
dc.subject.cnpqEngenhariaspt_BR
dc.titleEFICIÊNCIA ENERGÉTICA: UM ESTUDO DE CASO DE IMPLEMENTAÇÃO DE ILUMINAÇÃO DE LED EM ÁREA INDUSTRIApt_BR