dc.description.abstractIt is notorious the importance that a well-designed and well-designed scaling of the fire and panic combat system an take on a building. A fire fighting and panic system, plus assisting in the prevention of a disaster, helps save lives of occupants of the building in the event of a fire. Means of combat and fire must be precise, counting on a rapid combat to the fire. The Professor Wanderley Ferreira de Rezende State School, located in the municipality of Carmo da Cachoeira, is of educational occupation offering studies for elementary, middle and EJA, and it works in the three shifts. It does not have any system of protection and fire and panic control, as evidenced in the work of conclusion of course I. The present work has the objective to present the systems of combat and fire meeting the norms in force for such construction; through bibliographic review and on-site visits. In this way the best distributions for signs, emergency lighting, alarm and fire extinguishers, sizing of a hydrant system, and the composition of a fire brigade for the school. With the combat and fire project in panic the risk of fire in the building will be reduced.pt_BR
dc.description.resumoÉ notória importância que um dimensionamento bem feito e bem planejado do sistema de combate incêndio e pânico, pode ter em uma edificação. Um sistema de combate a incêndio e pânico além de auxiliar na prevenção de um sinistro ajuda a salvar vidas dos ocupantes da edificação caso ocorra um incêndio. Os meios de combate e incêndio devem ser precisos, contando com um combate rápido ao fogo. A Escola Estadual Professor Wanderley Ferreira de Rezende, localizada no município de Carmo da Cachoeira, é de ocupação educacional oferecendo estudos para ensino fundamental, médio e EJA, e funciona nos três turnos. Não possui nenhum sistema de proteção e combate ao incêndio e pânico. O presente trabalho tem como objetivo apresentar os sistemas de combate e incêndio atendendo as normas vigentes para tal edificação; por meio de revisão bibliográfica e visitas in loco. Deste modo foi identificado as melhores distribuições para as sinalizações, iluminações de emergência, alarme e extintores de incêndio, dimensionamento de um sistema de hidrante, além da composição de uma brigada de incêndio para a escola. Com o projeto de combate e incêndio em pânico os riscos de incêndio na edificação serão reduzidos.pt_BR
dc.description.provenanceSubmitted by Regiane Paulino (regiane.paulino@unis.edu.br) on 2019-03-12T17:07:56Z No. of bitstreams: 9 TCC II FINAL.pdf: 2245823 bytes, checksum: c499bcc68d31cfe3c320fafeddca0e8f (MD5) FOLHA 1.pdf: 1462648 bytes, checksum: 190568a3726455eb9e33ecf621eedf40 (MD5) FOLHA 2.pdf: 665420 bytes, checksum: fa0cb3ad29073ab3d17c116354c7f414 (MD5) FOLHA 3.pdf: 748610 bytes, checksum: 061b0b18e15860615127633143beefc4 (MD5) FOLHA 4.pdf: 771383 bytes, checksum: bb129bda155a81603efa5ecf8ddf48ef (MD5) FOLHA 5.pdf: 713800 bytes, checksum: a3c1a6615bb8fe842a7d1cd6fa5c7c15 (MD5) FOLHA 6.pdf: 688305 bytes, checksum: 7c10a674cd7b50faa44e0c3898a93e05 (MD5) FOLHA 7.pdf: 1028116 bytes, checksum: a384da22449d3c2a16743d03cac3341d (MD5) FOLHA 8.pdf: 529660 bytes, checksum: bc6e7dc10ef6caac1e40cb187426ab65 (MD5)en
dc.description.provenanceMade available in DSpace on 2019-03-12T17:07:56Z (GMT). No. of bitstreams: 9 TCC II FINAL.pdf: 2245823 bytes, checksum: c499bcc68d31cfe3c320fafeddca0e8f (MD5) FOLHA 1.pdf: 1462648 bytes, checksum: 190568a3726455eb9e33ecf621eedf40 (MD5) FOLHA 2.pdf: 665420 bytes, checksum: fa0cb3ad29073ab3d17c116354c7f414 (MD5) FOLHA 3.pdf: 748610 bytes, checksum: 061b0b18e15860615127633143beefc4 (MD5) FOLHA 4.pdf: 771383 bytes, checksum: bb129bda155a81603efa5ecf8ddf48ef (MD5) FOLHA 5.pdf: 713800 bytes, checksum: a3c1a6615bb8fe842a7d1cd6fa5c7c15 (MD5) FOLHA 6.pdf: 688305 bytes, checksum: 7c10a674cd7b50faa44e0c3898a93e05 (MD5) FOLHA 7.pdf: 1028116 bytes, checksum: a384da22449d3c2a16743d03cac3341d (MD5) FOLHA 8.pdf: 529660 bytes, checksum: bc6e7dc10ef6caac1e40cb187426ab65 (MD5) Previous issue date: 2018-12-04en
dc.languageporpt_BR
dc.publisherFundação de Ensino e Pesquisa do Sul de Minaspt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCentro Universitáriopt_BR
dc.publisher.initialsFEPESMIGpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectCombatept_BR
dc.subjectIncêndiopt_BR
dc.subjectEscolapt_BR
dc.subject.cnpqCNPQ::ENGENHARIAS::ENGENHARIA CIVILpt_BR
dc.titlePROPOSTAS PARA INSTALAÇÃO DOS SISTEMAS DE PREVENÇÃO E COMBATE A INCÊNDIO E PÂNICO DA ESCOLA ESTADUAL PROFESSOR WANDERLEY FERREIRA DE REZENDE NO MUNICÍPIO DE CARMO DA CACHOEIRA-MGpt_BR
dc.title.alternativeMARIELLE CRISTINA LEITE CHAGASpt_BR
dc.typeTrabalho de Conclusão de Cursopt_BR
Aparece nas coleções:Engenharia Civil

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
TCC II FINAL.pdf2,19 MBAdobe PDFVisualizar/Abrir
FOLHA 1.pdf1,43 MBAdobe PDFVisualizar/Abrir
FOLHA 2.pdf649,82 kBAdobe PDFVisualizar/Abrir
FOLHA 3.pdf731,06 kBAdobe PDFVisualizar/Abrir
FOLHA 4.pdf753,3 kBAdobe PDFVisualizar/Abrir
FOLHA 5.pdf697,07 kBAdobe PDFVisualizar/Abrir
FOLHA 6.pdf672,17 kBAdobe PDFVisualizar/Abrir
FOLHA 7.pdf1 MBAdobe PDFVisualizar/Abrir
FOLHA 8.pdf517,25 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.