Title: IMPOSSIBILIDADES TÉCNICAS NOS PROCESSOS DE SEGURANÇA CONTRA INCÊNDIO E PÂNICO: estudo de caso de edificações no sul de Minas Gerais
Other Titles: ROVIGO TOSATTI SOARES
metadata.dc.creator: Soares, Rovigo Tosatti
Mendes, Luana Ferreira
metadata.dc.description.resumo: Este trabalho tem por objetivo analisar as principais causas de impossibilidade técnica nos processos de segurança contra incêndio e pânico (PSCIP) para edificações existentes e construídas, apresentados na 3ª Companhia de Prevenção e Vistoria (3ª Cia PV) do Nono Batalhão de Bombeiros Militar (9º BBM) em Varginha-MG. Para o presente trabalho foram analisados os projetos técnicos (PT) e projetos técnicos simplificados (PTS), protocolados junto ao setor de análise da 3ª Cia PV no período de 2016 a 2018, sendo a 3ª Cia PV responsável por atender os municípios de Varginha, Elói Mendes, Três Pontas, Boa Esperança, Coqueiral, Guapé, Ilicínea e Santana da Vargem, cidades situadas no sul de Minas Gerais. Tal abordagem se faz necessária para delimitar quais as causas de impossibilidade técnica nos projetos de segurança contra incêndio e pânico e indicar soluções existentes às exigências de segurança atuais. O trabalho foi desenvolvido a partir do estudo de caso, no qual foram identificadas as principais impossibilidades técnicas e apresentadas as soluções de adequação às medidas de segurança pelo responsável técnico. Os principais problemas apresentados foram o não cumprimento da altura mínima para obstáculos representados por vigas e vergas de portas cuja altura mínima livre deve ser de 2,0 m, sendo proposto, pelos responsáveis técnicos, a instalação de sinalização de indicação de obstáculos nesses locais. O estudo demonstrou que, para edificações construídas ou existentes, a sinalização dos locais onde haja vigas ou vergas nos acessos ou escadas, com altura inferior a 2,0 m, atenderia requisitos mínimos de segurança, sem a necessidade adoção de medidas estruturais na edificação.
Abstract: This paper aims to analyze the main causes of technical impossibility in fire and panic safety processes for existing and constructed buildings, presented at the 3rd Company of Prevention and Inspection (3rd Cia PV) of the 9th Military Fire Brigade (9th BBM) in Varginha-MG. For the present study, the technical projects (PT) and simplified technical projects (PTS) were analyzed with the analysis of the 3rd Cia PV in the period from 2016 to 2018, and the 3rd Cia PV was responsible for serving the municipalities of Varginha, Elói Mendes, Três Pontas, Boa Esperança, Coqueiral, Guapé, Ilicínea and Santana da Vargem, cities located in the south of Minas Gerais. Such an approach is necessary to delineate the causes of technical impossibility in fire and panic safety projects and indicate existing solutions to current safety requirements. The work was developed based on the case study, in which the main technical impossibilities were identified and the solutions of adequacy to the safety measures were presented by the technician. The main problems presented were the non-compliance with the minimum height for obstacles represented by beams and gate yards whose minimum free height should be 2.0 m, and the technical responsible for the installation of obstacle indication signaling at these locations. The study showed that, for buildings constructed or existing, the signaling of places where there are beams or yards in accesses or stairs, with a height of less than 2.0 m, would meet minimum safety requirements without the need for structural measures in the building.
Keywords: PSCIP
Medidas de segurança
Impossibilidades técnicas
metadata.dc.subject.cnpq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
metadata.dc.language: por
metadata.dc.publisher.country: Brasil
Publisher: Fundação de Ensino e Pesquisa do Sul de Minas
metadata.dc.publisher.initials: FEPESMIG
metadata.dc.rights: Acesso Aberto
URI: http://repositorio.unis.edu.br/handle/prefix/912
Issue Date: 20-Jan-2019
Appears in Collections:Engenharia Civil EAD.

Files in This Item:
File Description SizeFormat 
Rovigo Tosatti Soares CIVIL.pdf598,42 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.