Please use this identifier to cite or link to this item: http://repositorio.unis.edu.br/handle/prefix/202
metadata.dc.type: Trabalho de Conclusão de Curso
Title: ESTUDO DA VIABILIDADE DO APROVEITAMENTO DE ÁGUA DE CHUVA E DO REÚSO DE ÁGUAS CINZAS EM UM EDIFÍCIO RESIDENCIAL MULTIFAMILIAR NO MUNICÍPIO DE ALFENAS
Other Titles: ELITON DA SILVA LEONARDO
metadata.dc.creator: Leonardo, Eliton da Silva
metadata.dc.contributor.advisor1: Ribeiro Júnior, Leopoldo Uberto
metadata.dc.description.resumo: O presente trabalho vem realizar um estudo de caso em um edifício residencial multifamiliar na cidade de Alfenas – MG, onde foi analisado utilização das águas de chuvas e águas cinzas nos seguintes locais: em bacias sanitárias, lavagem de carros, lavagem de pisos e rega de jardim. Estes locais não exigem que a água seja potável. Primeiramente foi realizada uma pesquisa em normas, livros, sites e outros trabalhos acadêmicos, afim de adquirir os conceitos teóricos para desenvolver este projeto. Através desta pesquisa foi possível estimar as variáveis existente no desenvolvimento do projeto, tais como estimativa populacional da edificação, pois esta está em fase de construção, e também foram estimadas as demandas de água da edificação. Foi realizado o dimensionamento de sistemas de aproveitamento de água de pluvial (SAAP) e reúso de águas afim de saber os custos com os empreendimentos. Para o SAAP o tempo de retorno fica em torno de 6 anos para o Caso 2 e 11 anos para o Caso 3, e percebeu-se que a seria inviável do ponto de vista econômico, por outro lado contribui para a preservação da água. Para o reúso de águas cinzas a coleta foi realizada por tubulações instalados nos locais de utilização onde o tratamento é menos complexo que é o caso da máquina de lavar roupas, tanque, chuveiro e lavatório, com isto foi escolhido uma Estação de tratamento de água cinza (ETAC). O tempo de retorno para reúso e de aproximadamente 3 anos e é totalmente viável economicamente. Foi proposto também neste trabalho um sistema misto com a junção dos SAAP e reúso, e verificou-se que também seria viável economicamente devido ao seu tempo de retorno ser de 3 anos e meio aproximadamente.
Abstract: The present work presents a case study in a multifamily residential building in the city of Alfenas, MG, where it was analyzed the use of rainwater and gray water in the following places: in sanitary basins, car wash, floor washing and irrigation garden. These locations do not require drinking water. First, a research was conducted on norms, books, websites and other academic works, in order to acquire the theoretical concepts to develop this project. Through this research it was possible to estimate the existing variables in the development of the project, such as the population estimate of the building, as it is under construction, and also the water demands of the building were estimated. The design of systems for the utilization of rainwater (SAAP) and reuse of waters was done in order to know the costs of the projects. For SAAP, the return time is around 6 years for Case 2 and 11 years for Case 3, and it was perceived that it would be impracticable from an economic point of view, on the other hand, it contributes to the preservation of water. For the reuse of gray water the collection was carried out by pipelines installed in the places of use where the treatment is less complex, such as washing machine, tank, shower and lavatory, with which a gray water treatment plant was chosen (ETAC). The return time for reuse is approximately 3 years and is fully economically feasible. It was also proposed in this work a mixed system with the SAAP junction and reuse, and it was verified that it would also be economically viable due to its return time being approximately 3 years and a half.
Keywords: Aproveitamento de água de chuva
Águas cinzas
Reúso
metadata.dc.subject.cnpq: CNPQ::ENGENHARIAS::ENGENHARIA CIVIL
metadata.dc.language: por
metadata.dc.publisher.country: Brasil
Publisher: Fundação de Ensino e Pesquisa do Sul de Minas
metadata.dc.publisher.initials: FEPESMIG
metadata.dc.publisher.department: Centro Universitário
metadata.dc.rights: Acesso Aberto
URI: http://repositorio.unis.edu.br/handle/prefix/202
Issue Date: 30-Nov-2016
Appears in Collections:Engenharia Civil

Files in This Item:
File Description SizeFormat 
TCC.pdf2,41 MBAdobe PDFView/Open
sistema hidraulico.pdf133,01 kBAdobe PDFView/Open
SAAP.pdf178,87 kBAdobe PDFView/Open
reuso de água cinza subsolo.pdf250,36 kBAdobe PDFView/Open
layout do edificio.pdf242,68 kBAdobe PDFView/Open
esgoto água cinza.pdf314,93 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.