Título : | MELHORIAS APLICADAS EM UM AQUECEDOR SOLAR DE BAIXO CUSTO (ASBC) COM BAIXO RENDIMENTO |
Otros títulos : | AILTON DE FARIA ROSA |
metadata.dc.creator: | Rosa, Ailton de Faria |
metadata.dc.contributor.advisor1: | Lopes, Alexandre de Oliveira |
metadata.dc.description.resumo: | Este trabalho consiste em fazer um estudo para identificar as causas do baixo desempenho de um aquecedor solar de Baixo custo ( ASBC), instalado no ano de 2008, em uma residência na cidade de Pouso Alegre, MG, o problema se agrava no inverno, onde sua eficiência chegava a ser quase nula, com base coletados nos dias 12 e 13 de julho foram identificados as principais causas e definidos as alterações que deveriam ser feitas, durante os dois dias foram coletados as temperaturas do interior do reservatório térmico em três alturas, fundo, meio e superfície, foram medidos também a temperatura de entrada da água aquecida dos coletores no reservatório e a temperatura ambiente , as medições ocorreram em um período de uma hora, tendo início as 6:00 e término as 18:00, durante os intervalos entre as medições também foram observados vários aspectos de funcionamento do sistema , após identificadas as causas do problemas, nos dias 20,21,22 e 23 de Agosto, foram feitas melhorias, e após a modificação ter sido concluída foram feitas nos dias 27 e 28 de agosto novas medições para avaliar os resultados das melhorias, com as mesmas condições das medições feitas anteriormente, foram utilizados gráficos e tabelas para facilitar a interpretação, foi feito levantamento do consumo de energia elétrica em 2010, o consumo de energia após as modificações foram analisados e comparado com os demais, antes das melhorias foi constatados que o sistema estava aquecendo somente um terço da água do reservatório, a parte superior, e as 18:00 a temperatura do reservatório já havia caído para 20°C, isso demostra a ineficiência do sistema e da isolação térmica, após as modificações ocorridas no sistema praticamente toda água no reservatório é aquecida atingindo uma temperatura de 48°C as 15:00, no dia seguinte as 6:00, a média de temperatura no reservatório é de 27,5°C, o que comprova a eficiência do novo isolamento térmico, os reflexos na conta de energia são imediatos, no mês e 2011, observando principalmente os meses de inverno onde os valores aumentam consideravelmente de outubro já houve uma redução de consumo. |
Resumen : | This work consists of making a study to identify the causes of the low low cost solar heater (ASBC) installed in 2008 in a residence in the city of Pouso Alegre, MG, the problem gets worse in winter, where its efficiency was almost nil based on July 12 and 13 were the main causes were identified and the changes that should be made during the two days were collected the temperatures of the interior of the thermal reservoir in three heights, bottom, middle and surface, the inlet temperature of the heated water was also measured. of the collectors in the reservoir and the ambient temperature, the measurements occurred in a one hour period, beginning at 6:00 and ending at 18:00, during breaks between measurements were also observed various aspects of system operation after After identifying the causes of the problems, on August 20, 21, 22 and 23, improvements, and after the modification was completed were made on August 27 and 28 new measurements to assess the results of improvements under the same conditions as those measurements previously made, graphs and tables were used to facilitate the interpretation, a survey was made of the electricity consumption in 2010, the consumption of energy after the modifications were analyzed and compared with the others before the improvements were found that the system was heating only one third of the water in the reservoir, the top, and by 18:00 the reservoir temperature had already dropped to 20 ° C, this demonstrates the inefficiency of the system and thermal insulation after modifications almost all the water in the reservoir is heated to a temperature 48 ° C at 15:00, the next day at 6:00, the average temperature in the 27.5 ° C, which proves the efficiency of the new thermal insulation, the reflections in the energy bill are immediate, in the month and 2011, observing mainly the months of winter where values rise considerably from October there has already been a reduction of consumption. |
Palabras clave : | Aquecedor Solar de Baixo Custo ASBC Problemas Melhorias |
metadata.dc.subject.cnpq: | CNPQ::ENGENHARIAS::ENGENHARIA MECANICA |
metadata.dc.language: | por |
metadata.dc.publisher.country: | Brasil |
Editorial : | Fundação de Ensino e Pesquisa do Sul de Minas |
metadata.dc.publisher.initials: | FEPESMIG |
metadata.dc.publisher.department: | Centro Universitário |
metadata.dc.rights: | Acesso Aberto |
URI : | http://repositorio.unis.edu.br/handle/prefix/1143 |
Fecha de publicación : | 30-nov-2011 |
Aparece en las colecciones: | Engenharia Mecânica |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Ailton De Faria Rosa.pdf | 5,97 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.